Skip to content

Industrial Instrument Model List by Industry (2026 Selection Guide)

Industrial instrument model shortlist for EPC engineers, plant maintenance teams and procurement specialists.

This guide maps common measurement duties to searchable model families from Rosemount, Endress+Hauser, Yokogawa, KROHNE, WIKA and SAMSON. Use it to create an RFQ shortlist; final selection must be checked against process data, hazardous-area classification and the current manufacturer datasheet.

Searching only for “a flowmeter” or “a pressure transmitter” rarely produces a reliable specification. A usable inquiry starts with the industry, measurement task, fluid, operating range, materials, process connection, output and certification. The tables below provide concrete model families for more than 50 common application duties.

How to use this industrial instrument model list

  1. Find the industry and measurement duty closest to your application.
  2. Shortlist two or three model families with the required measurement principle.
  3. Confirm minimum, normal and maximum pressure, temperature and flow.
  4. Confirm wetted materials, line size, connection, installation environment and approvals.
  5. Send the full process datasheet for configuration-code and accessory verification.

Important: Model-family inclusion is not a guarantee of suitability. Options within one model can differ substantially by sensor, range, liner, electrode, diaphragm, antenna, housing, protocol and approval.

1. Oil & Gas: Upstream, Midstream and Downstream

See our Oil & Gas: Upstream, Midstream and Downstream industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Wellhead, separator and pipeline pressureRosemount 3051S / 3051SMV; Yokogawa EJX530A / EJX110A; Endress+Hauser Cerabar PMP71B; WIKA S-20 / IS-3High-pressure range, H2S service, remote seals, Ex approval and SIL requirements
Custody, allocation and process flowRosemount 8800D; Endress+Hauser Promass F 300; Yokogawa ROTAMASS Total Insight; KROHNE OPTIMASS 6400Fluid phase, entrained gas, pressure loss, turndown and required uncertainty
Tank and separator levelRosemount 5408 / 5300 / 5900S; Endress+Hauser Micropilot FMR62B; KROHNE OPTIWAVE 7500Vapour, foam, dielectric constant, stilling well and overfill protection
Pipeline and vessel temperatureRosemount 3144P / 644; Yokogawa YTA610; WIKA T32.xS with TR10-B or TR10-CThermowell wake frequency, response time and hazardous-area certification
Severe-service control valveSAMSON Type 3251 valve, Type 3277 actuator, TROVIS 3793 or Type 3730-3 positionerPressure drop, cavitation, flashing, noise, shutoff class and fugitive emissions

2. Petrochemical and Chemical Processing

See our Petrochemical and Chemical Processing industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Reactor and column pressure / DPRosemount 3051 / 3051S; Yokogawa EJA110E / EJX110A; Endress+Hauser Deltabar PMD75B; KROHNE OPTIBAR DP 7060Corrosion-resistant diaphragm, capillary length, vacuum service and temperature limits
Conductive liquid flowRosemount 8700 Series; Endress+Hauser Promag P 300; Yokogawa ADMAG AXG; KROHNE OPTIFLUX 4300Liner and electrode compatibility, conductivity, grounding and empty-pipe detection
Mass and density flowEndress+Hauser Promass F 300; Yokogawa ROTAMASS Total Insight; KROHNE OPTIMASS 6400Two-phase flow, viscosity, density accuracy and process temperature
Steam and utility flowRosemount 8800D; Endress+Hauser Prowirl F 200; Yokogawa VY / digitalYEWFLO; KROHNE OPTISWIRL 4200Wet steam, Reynolds number, vibration, straight runs and compensation
Process control valve packageSAMSON Type 3241 or 3251, Type 3271 / 3277 actuator, Type 3730-3 positionerBody and trim metallurgy, characteristic, fail action, packing and diagnostics

3. Water and Wastewater Treatment

See our Water and Wastewater Treatment industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Raw water and distribution flowEndress+Hauser Promag W 400; KROHNE WATERFLUX 3070; Yokogawa ADMAG AXW; Rosemount 8705 sensor with 8712 transmitterBuried or flooded installation, IP68, low conductivity, grounding and remote mounting
Sludge and chemical dosingKROHNE OPTIFLUX 2300; Endress+Hauser Promag W 400; Yokogawa ADMAG AXGSolids content, abrasion, low velocity and chemical compatibility
Open tank and wet-well levelEndress+Hauser Micropilot FMR20; KROHNE OPTIWAVE 1400; Rosemount 3107 with 3490 controllerCondensation, foam, dead zone, obstruction and flood protection
Hydrostatic level and network pressureEndress+Hauser Waterpilot FMX21; WIKA A-10 / S-20; Rosemount 3051Cable material, vented reference, surge pressure and lightning protection
pH, conductivity and dissolved oxygenEndress+Hauser Liquiline CM44x; Yokogawa FLXA402Sensor cleaning, calibration access, fouling, temperature compensation and digital protocols

4. Power Generation and Steam Systems

See our Power Generation and Steam Systems industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Boiler drum level and feedwater DPRosemount 3051S / 3051SMV; Yokogawa EJX110A / EJX910A; Endress+Hauser Deltabar PMD75BStatic pressure, ambient temperature, impulse-line layout and density compensation
Main steam and auxiliary steam flowRosemount 8800D; Endress+Hauser Prowirl F 200; Yokogawa VY; KROHNE OPTISWIRL 4200High temperature, vibration, superheat compensation and straight-run availability
Turbine and boiler temperatureRosemount 3144P; Yokogawa YTA610; Endress+Hauser iTEMP TMT142B; WIKA T32.xS / TR10-BSensor redundancy, thermowell stress, drift monitoring and SIL
Condenser and cooling-water flowRosemount 8700 Series; Endress+Hauser Promag W 400; Yokogawa ADMAG AXW; KROHNE OPTIFLUX 2300Large line size, low pressure loss, grounding and remote electronics
Feedwater / steam control valvesSAMSON Type 3251 with Type 3277 actuator and TROVIS 3793 positionerHigh differential pressure, multistage trim, noise and fail-safe action

5. Food and Beverage Processing

See our Food and Beverage Processing industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Hygienic mass and density flowEndress+Hauser Promass Q 300 / Promass F 300; KROHNE OPTIMASS 7400; Yokogawa ROTAMASS Total Insight3-A or EHEDG needs, CIP/SIP temperature, drainability and surface finish
Hygienic electromagnetic flowEndress+Hauser Promag H 300; KROHNE OPTIFLUX 6300Process connection, liner, conductivity, empty-pipe detection and cleanability
Tank level and point levelEndress+Hauser Micropilot FMR63B / Liquiphant FTL43; Rosemount 1408HFoam, agitators, spray balls, hygienic connection and cleanability
Hygienic pressure and temperatureRosemount 3051HT; Endress+Hauser Cerabar PMP43 / iTHERM TrustSens TM371; WIKA PG43SA-S / TR21-AFlush diaphragm, fill fluid, surface finish, fast response and calibration
Aseptic valve automationSAMSON Type 3347 valve with Type 3277 actuator and compatible positionerSterile design, drainability, seat leakage, actuator air quality and cleaning cycle

6. Pharmaceutical and Biotechnology

See our Pharmaceutical and Biotechnology industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Bioreactor and process-vessel pressureRosemount 3051HT; Endress+Hauser Cerabar PMP43; WIKA PG43SA-SHygienic seal, low range, SIP temperature, fill fluid and documentation
Purified water / WFI flowEndress+Hauser Promag H 300; Promass Q 300; KROHNE OPTIMASS 7400Drainability, low flow, electropolished surfaces and calibration traceability
Non-contact hygienic levelRosemount 1408H; Endress+Hauser Micropilot FMR63BCondensation, foam, spray-ball interference and hygienic certification
Validated temperature measurementEndress+Hauser iTHERM TrustSens TM371; Rosemount 3144P; WIKA TR21-A / T32.xSSelf-calibration strategy, sensor matching, response and audit documentation
Clean-utility conductivity and pHEndress+Hauser Liquiline CM44x; Yokogawa FLXA402USP/EP limits, temperature compensation, calibration and sanitary sensor design

7. HVAC, Refrigeration and Building Utilities

See our HVAC, Refrigeration and Building Utilities industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Refrigerant and compressor pressureWIKA R-1 / S-20 / A-10; WIKA PSD-4 pressure switchRefrigerant compatibility, pulsation, pressure spikes and leak-tight connection
Filter and fan differential pressureWIKA A2G-50 / A2G-52; WIKA DPG40Very low DP range, overpressure, display, switch output and duct connection
Chilled-water and condenser-water flowEndress+Hauser Promag W 400; KROHNE OPTIFLUX 2300; Rosemount 8700 SeriesConductivity, glycol concentration, straight runs and energy calculation
Air and pipe temperatureWIKA TF45 / TR33; Rosemount 644; Endress+Hauser iTEMP TMT31Insertion length, response, condensation and transmitter output
Plant-room pressure indicationWIKA 232.50 / 233.50; A-10; PSD-4Gauge range, vibration, case filling, alarm setpoint and readability

8. SF6 Power Transmission and Distribution

See our SF6 Power Transmission and Distribution industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Continuous SF6 density monitoringWIKA GDM-100; WIKA GDHT-20Gas density reference, temperature compensation, alarm contacts and communication
SF6 gas analysis and quality checksWIKA GA11Moisture, purity and decomposition-product measurement before service
Gas handling and recoveryWIKA GIR-10; WIKA GVC-10Recovery efficiency, evacuation, filling control and gas loss prevention
Portable density indicationWIKA GDI-100-DField verification, digital logging and pressure / temperature compensation
Fixed gas leak monitoringWIKA GDS-MSensor placement, alarm thresholds, ventilation interlock and maintenance

9. Industrial Gases and Cryogenic Service

See our Industrial Gases and Cryogenic Service industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Gas mass flow and densityEndress+Hauser Promass F 300 / Promass A 300; KROHNE OPTIMASS 6400; Yokogawa ROTAMASS Total InsightGas density, low flow, pressure loss, cryogenic temperature and entrained liquid
Cylinder manifold and line pressureWIKA S-20 / IS-3 / 232.50; Rosemount 3051SOxygen cleaning, wetted material, pressure cycling and hazardous area
Cryogenic tank levelRosemount 5300 / 5408; Endress+Hauser Micropilot FMR62B; KROHNE OPTIWAVE 7500Low dielectric constant, vapour space, insulation and nozzle geometry
Gas temperatureRosemount 3144P; Yokogawa YTA610; WIKA T32.xS / TR10-CLow-temperature materials, insertion, response and sensor accuracy
Pressure-reducing controlSAMSON Type 41-23 self-operated regulator or engineered Type 3241 packageInlet / outlet pressure, capacity, seat tightness, materials and icing risk

10. Semiconductor and High-Purity Utilities

See our Semiconductor and High-Purity Utilities industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Ultra-high-purity gas pressureWIKA WU-20 / WU-25 / WU-26Electropolished wetted parts, surface finish, VCR connection and leak integrity
Low-flow process gas measurementEndress+Hauser Promass A 300; KROHNE OPTIMASS 3400; Yokogawa ROTAMASS Total InsightVery low flow, gas density, pressure loss, cleanliness and zero stability
UPW distribution flowEndress+Hauser Promag H 300; Yokogawa ADMAG AXG; KROHNE OPTIFLUX 6300Material purity, conductivity threshold, particle generation and clean connections
Chemical delivery pressure / levelRosemount 3051; Endress+Hauser Cerabar PMP43; Micropilot FMR63BChemical compatibility, remote seal, low range, vapour and contamination control
Cleanroom differential pressureWIKA A2G-50 / A2G-52Low-range stability, alarm output, room cascade and calibration access

11. Machinery Manufacturing and Automation

See our Machinery Manufacturing and Automation industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Hydraulic and pneumatic pressureWIKA A-10 / S-20 / PSD-4; WIKA MH-3-HYPressure spikes, vibration, connector, response time and switch outputs
Machine temperature monitoringWIKA TR33 / TF45; Rosemount 644; Endress+Hauser iTEMP TMT31Compact installation, vibration, sensor response and PLC interface
Coolant and process-water flowEndress+Hauser Picomag; KROHNE AF-E 400; Yokogawa ADMAG AXGSmall line size, conductivity, compact mounting and IO-Link needs
Lubrication and dosing flowEndress+Hauser Promass A 300; KROHNE OPTIMASS 3400Viscosity, very low flow, density, pressure loss and batching repeatability
Machine control valveSAMSON Type 3241 with Type 3271 / 3277 actuator and Type 3730-3 positionerAvailable air, fail action, cycling duty, leakage class and diagnostics

12. Construction and Mobile Machinery

See our Construction and Mobile Machinery industry solution for application context and engineering priorities.

Measurement dutySearchable model shortlistCritical checks before RFQ
Mobile hydraulic pressureWIKA MH-3-HY / MHC-1 / S-20Shock, vibration, pressure spikes, mobile connector and EMC
Local hydraulic pressure indicationWIKA 111.10 / 213.53Case filling, pulsation damping, range and mounting orientation
Oil and coolant temperatureWIKA TR33 / TF45Compact insertion, response, vibration and connector protection
Hydraulic alarm and switchingWIKA PSD-4Switching points, display orientation, output logic and ingress protection
Test and service referenceWIKA CPG1500 digital pressure gaugeAccuracy class, pressure adapter, data logging and calibration interval

Required data for an accurate quotation

Instrument groupMinimum RFQ information
FlowmeterFluid and composition; min/normal/max flow; pressure; temperature; density; viscosity; conductivity; line size; flange rating; accuracy; output; Ex approval.
Pressure / DPGauge/absolute/differential reference; range and static pressure; temperature; wetted material; connection; remote seal; capillary; output; SIL/Ex.
LevelTank dimensions; nozzle; medium and dielectric constant; temperature/pressure; foam, vapour, agitator; measuring range; overfill or SIL duty.
TemperatureRange; RTD or thermocouple; accuracy; insertion length; thermowell; process connection; response; transmitter; material; Ex approval.
Control valveFluid; min/normal/max flow; inlet/outlet pressure; temperature; line size/rating; body/trim material; fail action; leakage class; actuator supply; positioner protocol.

Frequently asked questions

Can one model be used in every industry?

No. A model family may support many configurations, but hygienic, corrosive, cryogenic, high-pressure, oxygen, SIL and hazardous-area duties require specific options and documentation.

Why include exact model numbers?

Model numbers make technical research and replacement planning faster. They also help procurement teams compare measurement principles and prepare a better RFQ. They do not replace sizing or configuration review.

Can Santan Fluid help with replacement and cross-reference?

Yes. Send the existing nameplate, configuration code, datasheet and process conditions. We can prepare a like-for-like check or a technically appropriate alternative shortlist.

Request a model selection and quotation

Send your medium, measuring range, operating pressure and temperature, line size, process connection, wetted material, signal, power supply, hazardous-area requirement and required quantity.

Email: sales@santanfluid.com
WhatsApp: +86 136 9022 318

Send Your RFQ

Product names and trademarks belong to their respective owners. Model availability and specifications may change. Always verify the latest official datasheet and ordering code before purchase.

Leave a Comment

Your email address will not be published. Required fields are marked *

Captcha loading...