Description
Yokogawa EJX120A Draft Range Differential Pressure Transmitter Technical Data and Selection Guide
Yokogawa EJX120A Draft Range Differential Pressure Transmitter is available from SANTAN for industrial pipeline instrumentation, replacement and export projects. This engineering page summarizes verified Yokogawa family data for model comparison and quotation preparation.
Verified Technical Specifications
| Brand / model | EJX120A |
|---|---|
| Measured variable / service | Draft-range differential pressure for liquid, gas or steam; also level, density and pressure |
| Accuracy / stability | +/-0.09% reference accuracy; +/-0.15% per year stability |
| Measuring range | Draft-range capsule; calibrated span and URL depend on order code |
| Response time | 150 ms |
| Process connection | IEC 61518-compatible process connection; manifold options by configuration |
| Output / communication | 4-20 mA with HART, BRAIN, FOUNDATION Fieldbus or PROFIBUS PA by order code |
| Approvals / safety | Exida and TUV SIL 2/3 certified; hazardous-area approvals by order code |
Final measuring span, wetted materials, process connection, output, enclosure and approval depend on the complete Yokogawa model and suffix code. Confirm the current General Specifications before ordering.
Typical Applications
- Furnace draft
- filter monitoring
- low differential pressure
- tank level
Data Required for Selection
| Process | Medium, minimum/normal/maximum pressure, temperature and density |
|---|---|
| Measurement | LRV, URV, required accuracy, response and static pressure |
| Mechanical | Process connection, manifold, wetted material and mounting arrangement |
| Electrical | Power supply, communication protocol, enclosure and Ex/SIL approval |
Related Products and Industry Solutions
- Yokogawa instrumentation range
- Pressure Measurement products
- Industrial measurement solutions
- Contact SANTAN engineering sales
Official Reference
Yokogawa official product page
Request a Quote
Send the full model code, quantity and process data to sales@santanfluid.com. WhatsApp +86 136 9022 3185 or +62 823 1767 3750. No online payment is required.
Standard Technical Specification Summary
Use these fields for preliminary selection. Final values depend on the complete manufacturer model code and selected options.
| Model | YOK-EJX120A |
|---|---|
| Measurement Range | Draft-range capsule; calibrated span and URL depend on order code |
| Accuracy | Configuration-dependent; confirm the accuracy class and calibrated range. |
| Process Connection | IEC 61518-compatible process connection; manifold options by configuration |
| Output Signal | Configuration-dependent; confirm analog, digital and communication requirements. |
| Certifications | Confirm hazardous-area, functional-safety, sanitary, marine or custody-transfer approvals by model code. |
| Application Industries | Application-dependent; confirm medium, process conditions and industry requirements. |