Description
The CHUANYI VFD is an anti-vibration vortex flowmeter for compatible liquid, gas and steam measurement. Its published configuration range covers several pressure classes, high-temperature options and common industrial communication protocols.
Verified technical overview
| Published accuracy | Liquid Class 0.75 / 1; gas Class 1 |
|---|---|
| Nominal size | DN15–DN600 |
| Pressure classes | 1.0 / 1.6 / 2.5 / 4.0 MPa; ANSI 150 / ANSI 300 |
| Process temperature | Standard -40 to +200°C; high-temperature -40 to +300°C |
| Ingress protection | IP65 / IP66 / IP67 |
| Published turndown | 1:20; up to 1:30 |
| Protocols | HART, Modbus RS485 and FF |
Engineering selection checklist
| Process medium | Phase, composition, conductivity or dielectric behaviour, solids and coating tendency |
|---|---|
| Operating envelope | Normal, start-up, cleaning and upset pressure, temperature and flow or level cases |
| Mechanical fit | Size, connection, materials, mounting geometry, accessibility and environmental protection |
| Control integration | Output, protocol, diagnostics, alarms, fail-safe action and power supply |
| Order validation | Confirm the complete configuration and current documents with CHUANYI before purchase |
Application guidance
Check fluid phase and density, Reynolds-number and minimum-velocity conditions, line size, straight-run availability, vibration sources, pressure and temperature, compensation requirements and protocol before selecting a VFD configuration.
Related products and resources
- Related measurement products
- CHUANYI product range
- CHUANYI MFE-S Multi-Function Electromagnetic Flowmeter
- CHUANYI MFC General-Purpose Electromagnetic Flowmeter
- CHUANYI MFD Slurry Electromagnetic Flowmeter
Official manufacturer source
Published values are model-family data and may vary by configuration. Confirm the complete order code, simultaneous limits, materials, approvals and current manufacturer documentation before purchase. No availability, price, sales ranking or project claim is implied.
Request a quotation
Send the model, process conditions, required configuration and quantity to sales@santanfluid.com, WhatsApp China +86 136 9022 3185 or WhatsApp Indonesia +62 823 1767 3750.
Standard Technical Specification Summary
Use these fields for preliminary selection. Final values depend on the complete manufacturer model code and selected options.
| Model | chuanyi-vfd |
|---|---|
| Measurement Range | Configuration-dependent; confirm the required span and complete model code. |
| Accuracy | Configuration-dependent; confirm the accuracy class and calibrated range. |
| Process Connection | Configuration-dependent; confirm size, rating, standard and wetted materials. |
| Output Signal | Configuration-dependent; confirm analog, digital and communication requirements. |
| Certifications | Confirm hazardous-area, functional-safety, sanitary, marine or custody-transfer approvals by model code. |
| Application Industries | Application-dependent; confirm medium, process conditions and industry requirements. |

Reviews