Skip to content

Chuanyi Integrated Instrumentation Solutions for Petrochemical, Water and Power Plants

A plant-wide Chuanyi solution can combine flow, pressure, radar level, temperature, control valves, valve positioners, electric actuators, analysers and PAS300 DCS integration around one process-data architecture.

Industrial projects rarely succeed by selecting each instrument in isolation. Measurement range, materials, diagnostics, communication, valve action, control strategy, maintenance access and spare-parts policy should be coordinated from the field device to the control room. This guide maps key Chuanyi product families to practical industry solution packages.

Chuanyi Product Architecture for Integrated Projects

LayerRepresentative Chuanyi productsProject role
Flow measurementMFE electromagnetic, vortex, metal-tube rotameter, DP, Coriolis, turbine, thermal mass and ultrasonic flowmetersLiquid, gas and steam measurement across process and utility systems.
Pressure and temperaturePDS pressure/DP/level/remote-seal transmitters; TTS smart temperature transmitter; WR thermocouples; WZ RTDsCore process variables, energy systems and equipment protection.
Level measurementMPS7000 / MPS5000 / MPS3000 radar; MGS guided-wave radar; MB magnetic level gauge; VS tuning fork switchContinuous level, interface and high/low-level protection.
Final control elementControl valves, ball valves, butterfly valves, HVP3 smart valve positionerModulating and isolation control with diagnostics.
Electric actuationM13/14 series linear intelligent electric actuatorsValve positioning from switching or 4-20 mA control signals.
Process and environmental analysisPS7000 process analysis; PS7400 CEMS; DT600; online water-quality analysersQuality, combustion, emissions and environmental compliance measurement.
Control systemPAS300 distributed control systemIntegrated process control, redundancy, communications and plant data.

Solution 1: Petrochemical and Chemical Process Unit

Process areaRecommended Chuanyi familiesEngineering value
Feed and product linesMFE electromagnetic, vortex, Coriolis, turbine or DP flowmeter according to fluidMatch measurement principle to conductivity, phase, pressure loss and accuracy.
Reactors and columnsPDS pressure/DP/remote-seal transmitter; MPS7000 radar; MGS guided-wave radarPressure, interface and level measurement under vapour, temperature and corrosion.
Control loopsChuanyi control valve with HVP3 smart positionerValve diagnostics, one-key initialisation and severe-environment protection.
Temperature pointsWR thermocouple, WZ RTD and TTS smart temperature transmitterSensor/transmitter package for reactors, heat exchangers and utilities.
Plant controlPAS300 DCSRedundant process control and integration of field signals and diagnostics.

The HVP3 positioner accepts 4-20 mA and digital signals. Chuanyi lists 0.5-class accuracy, 0.2-0.6 MPa air supply, low air consumption, 10-100 mm linear travel or 60-120 degree rotation, -40 to +80°C ambient rating for published configurations, IP66 protection and multiple gas/dust explosion-protection types. Its diagnostic functions and modular design are relevant to oil, chemical, metallurgy and power control loops.

Solution 2: Municipal Water and Wastewater

Process areaRecommended Chuanyi familiesKey checks
Raw and treated water flowMFE electromagnetic flowmeterPipe-full condition, low velocity, grounding, IP rating and remote mounting.
Dosing and sludgeMFE or suitable positive mass-flow technologyChemical compatibility, solids, coating and minimum stable flow.
Tank and wet-well levelMPS radar, HS-AW ultrasonic or hydrostatic PDS configurationFoam, condensation, obstruction, flood risk and mounting.
Water qualityOnline water-quality analyser / 70X3 explosion-proof water-quality analyser where applicableSensor cleaning, calibration, temperature compensation and area classification.
Control and optimisationPAS300 DCS with pump/valve integrationFlow-paced dosing, alarm management and historian/MES connection.

For water plants, a useful optimisation loop combines raw-water quality, inlet flow and PAC/PAM dosing rather than operating pumps from a fixed manual setpoint. This can improve chemical use and stabilise treated-water quality. See the Water & Wastewater solution page.

Solution 3: Power Generation and Steam

Measurement / control dutyChuanyi familiesEngineering priorities
Boiler and steam pressure/DPPDS pressure and differential-pressure transmittersStatic pressure, impulse piping, condensate pots, response and SIL requirement.
Steam and water flowVortex, DP or electromagnetic flowmeter according to mediumTemperature, compensation, straight runs, vibration and conductivity.
Coal, ash and liquid levelMPS7000 radar, MPS5000, MPS3000, RS/RAS/VS switchesDust, steam, false echoes, high temperature and independent overfill alarms.
Valve automationControl valve + HVP3, or M13/14 electric actuatorFail action, actuator force, control signal, diagnostics and maintenance.
Emissions monitoringPS7400 CEMSSample conditioning, analyser span, calibration and regulatory reporting.

MPS7000 Radar Level Application Notes

Chuanyi publishes the MPS7000 family for demanding level duties in petrochemical, power, metallurgy and cement applications. Product literature highlights a dual-CPU architecture, IP66/IP67 enclosure, surge protection, remote commissioning/diagnostics, waveform display and false-echo handling. High-temperature arrangements may use an extended antenna and purge/cooling configuration, with published design temperature up to 350°C for applicable designs. Tank geometry, nozzle, antenna, dielectric constant, vapour, foam, dust and agitators must still be reviewed for each application.

Project Deliverables to Request

  • Instrument index and tag-based datasheets
  • Model configuration and accessory schedule
  • Control-valve sizing, noise/cavitation review and actuator sizing
  • Hook-up drawings, manifolds, thermowells and mounting accessories
  • Hazardous-area, SIL and material certificates
  • I/O list, communication architecture and DCS integration scope
  • Factory acceptance test, calibration and commissioning documents
  • Recommended commissioning and two-year spare-parts list

Related industry pages: Chemical, Petrochemical, Power Generation and Water & Wastewater.

Request Chuanyi Product Selection Support

Send the medium, measuring range, pressure, temperature, line size, process connection, wetted material, output signal, power supply, hazardous-area requirement and quantity. For replacements, include a clear nameplate photo and the complete ordering code.

Email: sales@santanfluid.com
WhatsApp: +86 136 9022 318

Send Your RFQ

Technical reference: Chongqing Chuanyi official product portfolio and published product manuals. Verify current model availability, detailed specifications and certification against the latest manufacturer documents.

Leave a Comment

Your email address will not be published. Required fields are marked *

Captcha loading...