Description
Endress+Hauser Proline Promag P 300 Electromagnetic Flowmeter Technical Data and Engineering Selection Guide
Endress+Hauser Proline Promag P 300 Electromagnetic Flowmeter is supplied by SANTAN for industrial flow-measurement projects, replacement requirements and model-code review. The data below is intended for preliminary engineering selection and quotation preparation.
Verified Technical Specifications
| Product root | Proline Promag P 300 / 5P3B |
|---|---|
| Measured variables | Volume flow, conductivity and calculated mass flow |
| Nominal diameter | DN 15–600 (1/2–24 in.) |
| Measuring range | 4 dm3/min to 9,600 m3/h |
| Volume-flow error | Standard: ±0.5% of reading ±1 mm/s; option: ±0.2% of reading ±2 mm/s |
| Medium temperature | PFA: -20 to +150 °C; high-temperature PFA to +180 °C; PTFE: -40 to +130 °C |
| Maximum process pressure | PN 40 / Class 300 / 20K, configuration dependent |
| Wetted choices | PFA or PTFE liner; 316L, Alloy C22, tantalum, platinum or titanium electrodes |
These are product-family values, not a promise for every configuration. Final sizing, materials, approvals, accuracy, pressure and temperature limits must be confirmed against the complete manufacturer order code and current technical documentation.
Best-Fit Application
Use Promag P 300 when a conductive chemical or process liquid requires broad corrosion-resistance choices and a compact transmitter. Confirm minimum conductivity, liner compatibility, electrode material and grounding arrangement before sizing.
Quotation and Sizing Data Required
| Process | Fluid, phase, composition, conductivity/density/viscosity as applicable |
|---|---|
| Flow data | Minimum, normal and maximum flow; operating and reference conditions |
| Mechanical | Line size, schedule, connection standard, available straight run and orientation |
| Design limits | Operating/design pressure and temperature; wetted-material requirements |
| Electrical | Power, output/protocol, enclosure, hazardous-area and functional-safety requirements |
| Documentation | Required calibration, inspection, material and compliance documents |
Related Engineering Resources
- Magnetic flowmeter liner and electrode selection
- Coriolis vs electromagnetic flowmeter selection
- Industrial flowmeter installation checklist
- Promag H 300 for hygienic service
- Yokogawa ADMAG AXG alternative
- Flow measurement product category
Official Manufacturer Reference
Endress+Hauser official Promag P 300 product page and current technical downloads
Request a Quote
Send the complete model code, quantity and process data to sales@santanfluid.com. For a faster engineering review, use WhatsApp: +86 136 9022 3185 (China) or +62 823 1767 3750 (Indonesia). SANTAN will confirm the selectable configuration before quotation; no online payment is required.
Standard Technical Specification Summary
Use these fields for preliminary selection. Final values depend on the complete manufacturer model code and selected options.
| Model | EH-5P3B-PROMAG-P300 |
|---|---|
| Measurement Range | 4 dm3/min to 9,600 m3/h |
| Accuracy | Configuration-dependent; confirm the accuracy class and calibrated range. |
| Process Connection | Configuration-dependent; confirm size, rating, standard and wetted materials. |
| Output Signal | Configuration-dependent; confirm analog, digital and communication requirements. |
| Certifications | Confirm hazardous-area, functional-safety, sanitary, marine or custody-transfer approvals by model code. |
| Application Industries | Application-dependent; confirm medium, process conditions and industry requirements. |

Reviews
There are no reviews yet.