تخطي إلى المحتوى
المنتجات

Rosemount 3051CFP Integral Orifice Flow Meter

Rosemount 3051CFP integrates a self-centering orifice plate and precision meter run for small-line gas, liquid and steam DP flow measurement. Send the model code and process data to sales@santanfluid.com for technical review and quotation.

جميع المنتجات
SKU: RM-3051CFP الفئة: العلامة التجارية:

الوصف

Rosemount 3051CFP Integral Orifice Flow Meter Technical Data and Engineering Selection Guide

Rosemount 3051CFP Integral Orifice Flow Meter is supplied by SANTAN for industrial flow-measurement projects, replacement requirements and model-code review. The data below is intended for preliminary engineering selection and quotation preparation.

Verified Technical Specifications

النموذجRosemount 3051CFP Integral Orifice Flow Meter
الخدمةSmall-line gas, liquid and steam differential-pressure flow measurement
Primary elementSelf-centering integral orifice in a precision-honed meter run
Published accuracyUp to 1.75% of flow rate, application and configuration dependent
Line size1/2–1 1/2 in. (15–40 mm)
AssemblyFully assembled and leak tested
Connection choicesThreaded, socket-weld, beveled or flanged choices by order code
Output / diagnosticsCommunication, Bluetooth and diagnostics depend on ordered transmitter options

These are product-family values, not a promise for every configuration. Final sizing, materials, approvals, accuracy, pressure and temperature limits must be confirmed against the complete manufacturer order code and current technical documentation.

Best-Fit Application

Choose 3051CFP for small-bore lines where a factory-engineered meter run reduces uncertainty from actual pipe ID and plate-centering errors. Confirm bore, beta ratio, connection and sizing for the operating conditions.

Quotation and Sizing Data Required

ProcessFluid, phase, composition, conductivity/density/viscosity as applicable
Flow dataMinimum, normal and maximum flow; operating and reference conditions
MechanicalLine size, schedule, connection standard, available straight run and orientation
Design limitsOperating/design pressure and temperature; wetted-material requirements
ElectricalPower, output/protocol, enclosure, hazardous-area and functional-safety requirements
DocumentationRequired calibration, inspection, material and compliance documents

Related Engineering Resources

Official Manufacturer Reference

Emerson official Rosemount DP Flow Meters product data sheet, March 2025

طلب عرض سعر

Send the complete model code, quantity and process data to sales@santanfluid.com. For a faster engineering review, use WhatsApp: +86 136 9022 3185 (China) or +62 823 1767 3750 (Indonesia). SANTAN will confirm the selectable configuration before quotation; no online payment is required.

ملخص المواصفات الفنية القياسية

استخدم هذه الحقول للاختيار الأولي. تعتمد القيم النهائية على رمز نموذج المصنع الكامل والخيارات المحددة.

النموذجRosemount 3051CFP Integral Orifice Flow Meter
نطاق القياسيعتمد على التكوين؛ أكد النطاق المطلوب والكود النموذج الكامل.
الدقةيعتمد على التكوين؛ أكد فئة الدقة والنطاق المعاير.
توصيلة العمليةيعتمد على التكوين؛ أكد الحجم والتصنيف والمعيار والمواد المبللة.
إشارة الخرجيعتمد على التكوين؛ تأكيد متطلبات التناظري والرقمي والاتصالات.
الشهاداتأكد موافقات المناطق الخطرة والسلامة الوظيفية والصحية والبحرية أو نقل الحضانة برمز النموذج.
صناعات التطبيقيعتمد على التطبيق؛ أكد الوسط وظروف العملية ومتطلبات الصناعة.

التقييمات

لا توجد تقييمات بعد.

Be the first to review “Rosemount 3051CFP Integral Orifice Flow Meter”

لن يتم نشر عنوان بريدك الإلكتروني. الحقول الإلزامية مميزة *

Captcha loading...