Deskripsi
Rosemount 3051L Level Transmitter engineering overview
The Rosemount 3051L is the level-oriented member of the 3051 family. It measures hydrostatic head through a level flange or seal arrangement and is ordered as a differential- or gauge-pressure configuration according to the vessel and reference-leg design.
Verified model-family data
| Engineering item | Verified selection basis |
|---|---|
| Measurement basis | Differential- or gauge-pressure sensing for liquid level; density and head must be included in the engineered span. |
| Sensor range structure | The current 3051 data sheet lists 3051L differential and gauge variants within its range-and-sensor-limit table; select by calculated head, not tank height alone. |
| Reference accuracy | Up to 0.04% for the 3051 family; level-system performance also depends on seal, fill fluid, temperature and installation. |
| Rangedown | Up to 150:1 for the 3051 family, configuration-dependent. |
| Communication options | 4–20 mA HART, WirelessHART, FOUNDATION Fieldbus, PROFIBUS and 1–5 V low-power HART options. |
| Selectable materials | Process-wetted materials and seal components are selected for the medium, pressure and temperature. |
Configuration note: Values and features are option-dependent. Confirm the complete Emerson model code and current data sheet before final specification.
Application and ordering checklist
| Selection input | Mengapa itu penting |
|---|---|
| Vessel geometry and zero reference | Converts desired liquid level into the correct pressure span. |
| Liquid density at operating temperature | Directly affects hydrostatic head and calibrated range. |
| Open, closed or pressurized vessel | Determines gauge versus differential measurement and reference-leg treatment. |
| Flange, diaphragm and wetted materials | Checks process fit and corrosion compatibility. |
| Seal fill fluid and ambient/process temperatures | Controls response and temperature effects in the complete assembly. |
Relevant industry applications
- Closed-tank differential-pressure level measurement.
- Open-tank hydrostatic level measurement.
- Chemical, oil and gas, water and utility vessels when density and seal conditions are defined.
Related engineering resources
- Pressure-measurement catalog
- Gauge vs absolute vs differential pressure guide
- Pressure-instrument installation guide
- Oil and gas instrumentation solutions
- Chemical-process instrumentation solutions
- Rosemount 3051 Coplanar transmitter
- Rosemount 3051 In-Line transmitter
- Rosemount 3051S Coplanar transmitter
Official technical references
Emerson Rosemount 3051 product page | Emerson Rosemount 3051 product data sheet (October 2025)
Request an engineered quotation
Send the complete Rosemount 3051L model code or nameplate, quantity, measuring range, process conditions, connection, materials, output and required approvals to sales@santanfluid.com. For faster engineering review, contact WhatsApp China +86 136 9022 3185 or WhatsApp Indonesia +62 823 1767 3750. SANTAN will confirm the selectable configuration before quotation.
Ringkasan Spesifikasi Teknis
Gunakan bidang ini untuk pemilihan awal. Nilai akhir tergantung pada kode model lengkap pabrikan dan opsi yang dipilih.
| Model | Transmitter Level Rosemount 3051L |
|---|---|
| Rentang Pengukuran | Tergantung konfigurasi; konfirmasi rentang yang diperlukan dan kode model lengkap. |
| Akurasi | Bergantung konfigurasi; konfirmasi kelas akurasi dan jangkauan yang dikalibrasi. |
| Koneksi Proses | Bergantung konfigurasi; konfirmasi ukuran, peringkat, standar dan material basah. |
| Sinyal Output | Tergantung konfigurasi; konfirmasikan persyaratan analog, digital dan komunikasi. |
| Sertifikasi | Konfirmasikan persetujuan area berbahaya, keselamatan fungsional, saniter, kelautan atau kepemilikan transfer dengan kode model. |
| Industri Aplikasi | Bergantung aplikasi; konfirmasi media, kondisi proses dan persyaratan industri. |

Ulasan