الوصف
Endress+Hauser Proline Promag H 300 Hygienic Electromagnetic Flowmeter Technical Data and Engineering Selection Guide
Endress+Hauser Proline Promag H 300 Hygienic Electromagnetic Flowmeter is supplied by SANTAN for industrial flow-measurement projects, replacement requirements and model-code review. The data below is intended for preliminary engineering selection and quotation preparation.
Verified Technical Specifications
| Product root | Proline Promag H 300 / 5H3B |
|---|---|
| Measured variables | Volume flow, temperature, conductivity and calculated variables |
| نطاق القياس | 0.06 dm3/min to 600 m3/h |
| Volume-flow error | Standard: ±0.5% of reading ±1 mm/s; option: ±0.2% of reading ±2 mm/s |
| Medium temperature | -20 to +150 °C |
| Maximum process pressure | PN 40 / Class 150 / 20K, configuration dependent |
| Wetted choices | PFA liner; 316L, Alloy C22, tantalum or platinum electrodes |
| Protection / communication | IP66/67 and IP69; protocol availability depends on configuration |
These are product-family values, not a promise for every configuration. Final sizing, materials, approvals, accuracy, pressure and temperature limits must be confirmed against the complete manufacturer order code and current technical documentation.
Best-Fit Application
Use Promag H 300 for conductive hygienic liquids where cleanability, process connection, seal elastomer, surface requirements and documentation must be defined from the plant standard rather than assumed from the family name.
Quotation and Sizing Data Required
| Process | Fluid, phase, composition, conductivity/density/viscosity as applicable |
|---|---|
| Flow data | Minimum, normal and maximum flow; operating and reference conditions |
| Mechanical | Line size, schedule, connection standard, available straight run and orientation |
| Design limits | Operating/design pressure and temperature; wetted-material requirements |
| Electrical | Power, output/protocol, enclosure, hazardous-area and functional-safety requirements |
| Documentation | Required calibration, inspection, material and compliance documents |
Related Engineering Resources
- Magnetic flowmeter liner and electrode selection
- Coriolis vs electromagnetic flowmeter selection
- Industrial flowmeter installation checklist
- Promag P 300 for chemical service
- Promass F 300 Coriolis alternative
- Flow measurement product category
Official Manufacturer Reference
Endress+Hauser official Promag H 300 product page and current technical downloads
طلب عرض سعر
Send the complete model code, quantity and process data to sales@santanfluid.com. For a faster engineering review, use WhatsApp: +86 136 9022 3185 (China) or +62 823 1767 3750 (Indonesia). SANTAN will confirm the selectable configuration before quotation; no online payment is required.
ملخص المواصفات الفنية القياسية
استخدم هذه الحقول للاختيار الأولي. تعتمد القيم النهائية على رمز نموذج المصنع الكامل والخيارات المحددة.
| النموذج | EH-5H3B-PROMAG-H300 |
|---|---|
| نطاق القياس | 0.06 dm3/min to 600 m3/h |
| الدقة | يعتمد على التكوين؛ أكد فئة الدقة والنطاق المعاير. |
| توصيلة العملية | يعتمد على التكوين؛ أكد الحجم والتصنيف والمعيار والمواد المبللة. |
| إشارة الخرج | يعتمد على التكوين؛ تأكيد متطلبات التناظري والرقمي والاتصالات. |
| الشهادات | أكد موافقات المناطق الخطرة والسلامة الوظيفية والصحية والبحرية أو نقل الحضانة برمز النموذج. |
| صناعات التطبيق | يعتمد على التطبيق؛ أكد الوسط وظروف العملية ومتطلبات الصناعة. |

التقييمات